High Pressure Capillary Rheograph – Rheology is the study of flow and deformation of materials under applied forces. The measurement of rheological properties is applicable to all materials. John Morris – Rheometers

The Rheograph 25 are new designed user-friendly High Pressure Capillary rheometer with over again enlarged shear rate range, higher test piston force (25 kN) and a huge variety of options. The new developed Windows database Software allows the parameterisation, the online monitoring as well as the free definable evaluation.
Benefits
  1.  Adaptive Pressure Signal Processing: A unique way for using almost 100% of your pressure transducer range, down to the lowest readings without noise.
  2. Goettfert’s Adaptive Pressure Signal Processor allows readings of only 0.005% of full range of the pressure transducer used. In practical terms, this means that you can use a 2000 bar transducer to see differences of only 0.1 bar.
  3. All of Goettfert’s special CAN bus pressure transducers are rigorously and individually tested and calibrated. Based on our ISO 9001 QS manual, only certified tools are used, and all data points are loaded into the transducer for unsurpassed and automated calibration curve fitting. Testing protocols are available with each transducer.

 

Specifications

Model : GOTTFERT 012013, Germany

Range: Max temperature 400° C

  • Twin barrel system 15 mm design
  • Speed range 0,00004 – 40 mm/sec (= 1:1.000.000)
  • Internal PC with 5,7″ color-QVGA-touchscreen for full controlling and data measuring und user-friendly menu interface
  • Windows database software for parameterisation, online monitoring as well as the free definable evaluation, data transfer via Ethernet port
  • Compact service-friendly construction with easy accessible components
  • Test barrel and optional equipment up to 5 pressure transducers and up to 3 force transducers
  • Temperature range up to 400°C (500°C optional) via temperature control algorithm
  • 5 calibration data sets for any temperature inside of the range (including respective controlling parameter sets)
  • Automatic pressure transducer recognition with (GOETTFERT pressure transducers). Simply connecting and start! No input required anymore
  • Drive torque monitoring and display
  • Infinitely variable manual controlling of the test piston
  • Integrated timer for temperature set values
  • Online display of the device status